1. CE Accredited
3. A LED screeen control panel
4. Time setting of 24 hours
5.Auto-defrost with the option of a Solenovid valve or electrical heating.
6. Correct humidity control.
7. rotational compressor 3 minute delay to safeguard the compressor
8. using an external hose to drain
9. Function of the fault sensor's indicator illumination
10. The water tank and pump are optional.
Model | DK-138E |
Dehumidify capacity | 138L /Day |
Voltage | 220V-240V/50HZ |
Input current | 7.8A |
Input power | 1.45KW |
Circulating air | 1000m³/h |
Applied area | 120-150 m2(Height2.6m) |
Control way | Auto/Manual |
Drainage | Drainage hose |
Noise | ≤ 60dB(A) |
Net weight | 55 KG |
Machine size | 480X420X900mm |
Attention:
1. If the set humidity is higher than the actual humidity, the dehumidifier will not work.
2. When the dehumidifier is working, after the compressor starts to work, the fan and compressor will run for at least 3 minutes before they stop working.
Action: After the compressor stops working, it must pass 3 minutes before the compressor can be started.
3. If working at a lower temperature, the dehumidifier will automatically judge the system temperature, so as to achieve automatic defrosting.
When defrosting, the defrosting indicator light is on, the fan works, and the compressor automatically stops working.
4. The system has an automatic memory function. After all mode settings are completed, when the system suddenly encounters a problem during work, the power is cut off, the system can automatically store the current operating state before the power off.
The next time when the system is powered on, it will automatically enter the operating mode it was in before the power off.
5 Humidity can be set in the range of 10%-90%.
6. If the dehumidifier will not be used for a long time, please remove the power cord or power off.
7. Automatic detection of wet/humidity sensor failure:
1)When the system detects that the temperature sensor is out of its limited range, the system enters the temperature sensor failure mode.
In this mode, the LED displays the temperature fault code "E1", and the system operates cyclically with dehumidification within 30 minutes and defrost operation within 15 minutes;
2) When the system detects that the humidity sensor is out of its limited range, the system enters the humidity sensor failure mode,
In this mode, the LED displays the humidity fault code "E2" and the system enters continuous dehumidification operation;
3) when the temperature/humidity sensor fault is eliminated, the system enters normal operation
The commercial dehumidifier is widely used in offices, libraries, computer rooms, precision instrument rooms, hospitals and warehouses, chemical fiber, pharmaceuticals, glass, food, electronics, metallurgy, printing, warehouses, basements, archives, Electricity, telecommunications, cigarettes, medicine, printing, tea, leather, textiles and other places that require humidity.
During the using process, it can help user to eliminate various losses caused by humidity, and make the production and storage of products can be carried out in the right humidity, so as to ensure the products quality.
You can tell us the area of the room you need to dehumidify or humidify, our engineers will design which product to use according to your requirements.
Q2, Can I order one sample to check your quality?
For sure, we can offer one sample within 7 days, but you need to afford the courier cost.
Q3, What about the lead time?
Normally 15-20 days after signed contract.
Q4, What's the payment terms?
T/T 30% deposit in advance, and 70% balance against the shipment documents or L/C at sight.
Duokai will keep on our best to manufacture the first-rate dehumidifiers. If you are interested in any of our portable dehumidifiers for large room,warehouse,gym, laboratory, basement and greenhouse, please feel free to contact us for more information. We are looking forward to forming business relations with you.